User Profile
Collapse
-
-
I've replaced several Batts on the Biz 4750 because of date and time not holding. But recently had a 4752 where it would copy fine but wouldn't scan or...😎 1Leave a comment:
-
Just had this on a 4752 and turned out the date & time were wrong. Check the memory battery if it keeps losing the date & time.👍 3Leave a comment:
-
The first thing comes to mind is the tie. I could never figure out why we had to wear tie back then. My guess is so the owners could charge more by making...👍 2Leave a comment:
-
Speaking of finishers I'm sure the old timers will remember that early on the OEM's didn't make a finisher for their machines, they were made and sold...👍 1Leave a comment:
-
Hi,
In your previous post you said you were going there on Monday with drums & developer units. Did you replace drums and / or dev u...Leave a comment:
-
Like I mentioned previously something doesn't add up and OP post is really an unsolved mystery. I don't believe settings could have caused a fuser "melt...Leave a comment:
-
I'm sure with all the "ammunition" you are bringing you will fix it. Let us know what fix was?...Leave a comment:
-
Greetings Hans, 96mm is about the same circumference as drums. Since drums are over life I would start there. Would replace magenta drum first. If one...👍 2Leave a comment:
-
Most OEM's had trouble with corona end caps arcing / shorting. It was just the nature of coronas & high voltage finding easiest path to ground....👍 3Leave a comment:
-
The Jap companies will never admit to an issue usless they have a solution to fix. Also the tech help line has been the same for 40 years, same old story...👍 2Leave a comment:
-
C554 fuser cleaning rollers, update
Well this post is follow up to my recent post regarding fuser cleaning rollers. The reason I asked about removing them is I was going on a call for 3102...Last edited by copyman; 2 weeks ago.👍 1 -
-
So just to be clear, the rollers cannot be removed from the "8" series or machine will code?...Leave a comment:
-
C554 & C558 fuser cleaning rollers
I've read on this forum about leaving the cleaning rollers out of the C554-C754 fuser unit and still works well. Does this also apply to the 8 series... -
Take drums & DV units out and you can access the 4 laser windows.
Don't forget to do the gradation adjustment after.Leave a comment:
-
Are you trying physical or logical format? I would try physcial but keep in mind it takes a long time to format.
There has been posts on...Leave a comment:
-
Like I wrote in my OP something doesn't add up and has to be more to this story......👍 1Leave a comment:
-
Synthohol is right about the date & time. Especially with the 4700 series. I'm finding those small backup batts going bad a lot lately. Loses the...Leave a comment:
No activity results to display
Show More
Leave a comment: